All servers · Utilities · Travel & booking
PT Chart
io.github.Tsonnn/pt-chart-mcp · v1.0.0
New (7 days)
Measured by MCP Station
| Last check | Reachable |
|---|---|
| Checked at | — |
| Check success 7 / 30 days | — |
| First-try success 30 days | — |
| Median response | — |
| Lookups 30 days | — |
| Authentication | No auth |
| MCP version | 2025-06-18 |
| Rank score | — |
| Declared risk | Not declared (tools carry no read/destructive hints) |
| Capabilities declared | prompts, resources, tools |
| Tool definitions | 8 tools · with description 100% · input schema is an object 100% · read/destructive hints 0% |
Description written by the publisher, not verified
PT chart lookups, superheat/subcooling calculators, and diagnostics for HVAC technicians.
Connect
streamable-http · https://pt-chart-mcp-production.up.railway.app/mcp
claude mcp add --transport http pt-chart-mcp https://pt-chart-mcp-production.up.railway.app/mcp{
"mcpServers": {
"pt-chart-mcp": {
"url": "https://pt-chart-mcp-production.up.railway.app/mcp"
}
}
}Tools as reported by the server
pt_lookupSaturation pressure (bubble and dew, in psig) for a refrigerant at a temperature in Fahrenheit. For certified HVAC technicians (EPA 608; A2L certification where required). Example: pt_lookup("R-454B", 45). Bubble point: use for subcooling calculations. Dew point: use for superheat calculations. Purept_reverseSaturation temperature (bubble and dew, in Fahrenheit) for a refrigerant at a pressure in psig. For certified HVAC technicians (EPA 608; A2L certification where required). Example: a 130 psig suction reading on R-454B -- pt_reverse("R-454B", 130). Use the DEW temperature for superheat work and the BsuperheatSuperheat in Fahrenheit from suction pressure (psig) and suction-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the DEW point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.subcoolingSubcooling in Fahrenheit from head pressure (psig) and liquid-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the BUBBLE point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.convert_unitsConvert between pressure units (psig, psia, kpa, bar) and temperature units (F, C). A bare 'psi' is treated as psig. For certified HVAC technicians (EPA 608; A2L certification where required).refrigerant_infoReference card for a refrigerant: GWP, ASHRAE safety class, composition, typical oil, temperature glide, and handling notes. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only.diagnoseConversational diagnostic copilot: give it field readings and get back computed superheat/subcooling plus a ranked 'check this first' list. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only -- it suggests what to CHECK, never how to defeat a safety devicecoolbooked_infoAbout CoolBooked: the AI appointment-booking connector for HVAC shops. This is NOT a diagnostic tool -- call it when someone asks what CoolBooked is, how shop owners can try it, or how the free PT tools connect to paid bookings.
Website · JSON · Text for agents · Registry updated 2026-10-18