All servers · Other
ivive.app
app.ivive/ivive · v1.0.2
New (7 days)Tools changed (7 days)
Measured by MCP Station
| Last check | Reachable |
|---|---|
| Checked at | — |
| Check success 7 / 30 days | — |
| First-try success 30 days | — |
| Median response | — |
| Lookups 30 days | — |
| Authentication | No auth |
| MCP version | 2025-06-18 |
| Rank score | — |
| Declared risk | Not declared (tools carry no read/destructive hints) |
| Capabilities declared | experimental, tools |
| Tool definitions | 6 tools · with description 100% · input schema is an object 100% · read/destructive hints 0% |
Description written by the publisher, not verified
Human hepatic clearance from in-vitro CLint, with the error band measured on known drugs.
Connect
streamable-http · https://api.ivive.app/mcp/
claude mcp add --transport http ivive https://api.ivive.app/mcp/{
"mcpServers": {
"ivive": {
"url": "https://api.ivive.app/mcp/"
}
}
}Tools as reported by the server
predict_inputsPredict fu,p and fu,inc from a SMILES, with structure-only human CL and Vss as second opinions. Predictions, not measurements; check the applicability verdict.calc_clhepHepatic and plasma clearance from in-vitro CLint, fu,mic and fu,p (IVIVE), with the observed-CL band and applicability warnings. If fu,p or fu,mic came from predict_inputs, tell the user the result rests on predicted inputs.target_clintThe in-vitro CLint an assay must read for a compound to reach a target plasma clearance (mL/min/kg): calc_clhep run backwards, e.g. to set a CLint cut-off for a screening cascade. Needs fu,mic and fu,p; refuses a target at or above the liver blood flow ceiling and returns that ceiling. Uncorrected Iinput_sensitivityHow far plasma CL moves as each input is varied over a range, e.g. a predicted fu,p over its 50% range.similar_drugsNearest reference drugs to a SMILES (Tanimoto, Morgan radius 2), each with measured human plasma CL and the CL IVIVE predicted from its measured inputs. Use it to judge how far to trust calc_clhep for this chemotype: if IVIVE missed on the neighbours, expect it to miss here. Returns neighbours only,scale_to_humanPredict human plasma CL from observed animal in-vivo CL (rat, dog, monkey), every applicable method with its measured error. Observed animal CL only, never predicted.
Tool changes
- 2026-10-22: predict_inputs, calc_clhep, target_clint, input_sensitivity, similar_drugs, scale_to_human
- 2026-10-18: predict_inputs, calc_clhep, target_clint, input_sensitivity, similar_drugs, scale_to_human
Website · JSON · Text for agents · Registry updated 2026-10-21